#7202. Electrocautery-induced molten metal particle generation from total joint replacements: Morphology and chemistry

February 2027publication date
Proposal available till 11-05-2025
4 total number of authors per manuscript0 $

The title of the journal is available only for the authors who have already paid for
Journal’s subject area:
Mechanical Engineering;
Mechanics of Materials;
Condensed Matter Physics;
Materials Science (all);
Places in the authors’ list:
place 1place 2place 3place 4
FreeFreeFreeFree
2510 $1340 $1170 $1000 $
Contract7202.1 Contract7202.2 Contract7202.3 Contract7202.4
1 place - free (for sale)
2 place - free (for sale)
3 place - free (for sale)
4 place - free (for sale)

Abstract:
Electrosurgical techniques are used during surgery to cauterize, and their damaging effects have primarily been documented in terms of tissue necrosis, charring, and localized heat accumulation. Metallic implants as well as the surgical blade can experience incidental electrosurgical current arcing that results in the generation and transfer of melted metallic particles. This work examines the composition, particle size distribution, and chemical state of the melted alloy surfaces and particles produced in vitro. Using scanning electron microscopy and energy dispersive spectroscopy, a flash-melting particle generation phenomenon between source 304 SSL blades and polished cobalt-chromium-molybdenum (CoCrMo) and titanium-6-aluminum-4-vandaium (Ti6Al4V) surfaces was documented where 304 SSL mixed heterogeneously with the CoCrMo and Ti6Al4V ejecting “splatter” particles from the cautery site. The spherical micron-sized particles were embedded with sub-micron-sized particles with 42% of the total sample population measuring between 0.25 and 0.35 ?m in diameter. CoCrMo-304 SSL particles were principally made of high concentrations of iron, oxygen, and nickel with embedded sub-micron-sized particles containing oxygen, chromium, and cobalt with lower concentrations of iron and molybdenum. Ti6Al4V-304 SSL interactions resulted in similar micron-sized particles made up of high concentrations of iron, nickel, and chromium with embedded sub-micron-sized particles containing titanium, oxygen, and small amounts of aluminum. X-ray photoelectron spectroscopy of damaged CoCrMo surfaces confirmed the presence of chromium (VI) following dry electrocautery contact in coagulation mode. The structural effects of electrocautery-induced damage are becoming visible in retrieval analysis, but the long-term physiological implications during the lifetime of the implant from this damage mode have yet to be defined.
Keywords:
CoCrMo; debris; electrocautery; orthopedic implants; Ti6Al4V

Contacts :
0